Permit: T02CM01848

Parcel: 110064970


Addresses:

2970 N CARDELL CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/20/2002 FRAMING Approved IVRS - Inspection 0000*
06/19/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE 2) BLOCKING FOR DRYWALL SHEAR MISSING IN GARAGE WEST WALL-7 FEET 2) FIRE BLOCK EAST BEDROOM FURRED OUT WALL 3) ITEM 6 FROM PRIOR INSPECTIONS NOT COMPLIED WITH
06/11/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE BLOCKING FOR TOP PLATE DRYWALL SHEARWALL NAILING 2) NAIL PROTECT PLUMBING WITHIN 1 14/" OF STUD SURFACE 3) NO GAS PRESSURE TEST 4) HALL BATH WATER CLOSET DOES NOT HAVE 15" CLEARANCE TO TUB 5) FIRE BLOCK BEDROOM WINDOW DEAD SPACE 6) FIRE BLOCK LEDGER WALLS BELOW BOTTOM CHORD OF TRUSSES 7) BAD PEX CONNECTION ABOVE RANGE DUCTS RESTRICTED
05/31/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) GARAGE SHEARWALL 1 ABOVE DORP CEILING OSB OK