Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM01830
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/26/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
06/24/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLATFORM SQUARE UP OSB AND NAIL TO 2 X 6'S 2) RUN STIFF LEG AT LONG SPAN 3) REAR SHEAR WALL IS NOT CONTINOUS TO TOP OF ROOF DECK 4) BACKING AT SHOULDER 5) SECURE RECESSED CAN IN NICHE 6) FINISH FIREPLACE INSTALLATION 7) MORE NAILS IN VIEGA POSTS AT SUPPORT |