Date Description Inspector Results Comments
06/26/2002 FRAMING Approved IVRS - Inspection 0000*
06/24/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) PLATFORM SQUARE UP OSB AND NAIL TO 2 X 6'S 2) RUN STIFF LEG AT LONG SPAN 3) REAR SHEAR WALL IS NOT CONTINOUS TO TOP OF ROOF DECK 4) BACKING AT SHOULDER 5) SECURE RECESSED CAN IN NICHE 6) FINISH FIREPLACE INSTALLATION 7) MORE NAILS IN VIEGA POSTS AT SUPPORT