Permit: T02CM01825

Parcel: 136341840


Addresses:

7641 E LAKESIDE DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/13/2002 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ 1) (YARD LINE TO FURNACE)
05/09/2002 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ 1) GAS LINE NOT HOLDING PRESS "0" ON GAUGE, YOU NEED 10 POUND FOR MINIMUM IS MINUTES. WHILE INSPECTOR IS ON SITE 2) DEPTH AND INSTALLATION
04/17/2002 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED A TWO DIMENSIONAL PIPE DIAGRAM SHOWING GAS PIPING FROM METER TO APPLIANCES INCLUDING PIPE MEASUREMENTS 2) APPROX 90 PLUS FEET METER TO 3/4" LINE ENTERING THE HOUSE 30 PIPE IS TOO SMALL (175 DEMAND-111 DELIVERY AT HOUSE WALL YOU HAVE APPROX 150 PLUS FT OF) 4) NEED 1/4" PITCH FOR FT GAS FLUE