Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/20/2002 |
STEM WALL/RETAINING WALL |
|
Approved |
|
| 06/03/2002 |
STEM WALL/RETAINING WALL |
|
Partial Approval |
PRE GROUT OK BOND BEAM. |
| 05/29/2002 |
STEM WALL/RETAINING WALL |
|
Denied |
IVRS - Inspection 0999*1.) PLAN SHOWS 6' WALL YOU BUILT 7'5". PROVIDE NEW APPROVED PLANS FROM DSD. NOTE: FOOTING IS ONLY 24" WIDE. 2.) BOND BEAM TAPE IS COVERING VERTICAL GROUT CELLS. I NEED TO SEE TO BOTTOM 3. REBAR DOES NOT EXTEND INTO TOP WALL. 4.) CLEAN OUT REQUIRED FOR GROUT LIFTS. 5.) VERTICAL CELLS WITH REBAR GROUTED TO 6' WITHOUT INSPECTION. PROVIDE APPROVED FIX TO ADD TOP 2 COURSES. |
| 05/24/2002 |
STEM WALL/RETAINING WALL |
|
Denied |
IVRS - Inspection 0920*LOCKED NO ACCESS. |