Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM01789
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/01/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/29/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) P.A. NOT MISSED, ALL PA'S IN PLACE 2) STRAP FRONT PORCH BEAM 3) INSTALL H.3 AT FRONT PORCH 2 X 6 STUDS TO ROOF DIAPHRAM 4) CHANGE OUT NAILS IN HANGER FOR FIREPLACE HEADER USE 16D'S PER SIMPSON | |
10/25/2002 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) PORCH TO BEAM CONNECTIONS NOT DONE 2) MISSED ONE PA ON WEST WALL FRONT SHEAR 3) SW4, SW3 SHEAR SHORT NAILED 4) DOUBLE STUDS UNDER GIRDER 5) CHANGE NAIL IN HUS26-TO 16D'S 6) ADD H34 TO FRONT PARAPET ROOF DIAPHRAM PER DETAIL 7) ADD LATERAL BRACES PER TRUSS DRAWINGS | |
10/21/2002 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) GARAGE ROOF AND CLIP OK |