Permit: T02CM01789

Parcel: 117034020


Addresses:

626 E 2ND ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM01789

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/29/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) P.A. NOT MISSED, ALL PA'S IN PLACE 2) STRAP FRONT PORCH BEAM 3) INSTALL H.3 AT FRONT PORCH 2 X 6 STUDS TO ROOF DIAPHRAM 4) CHANGE OUT NAILS IN HANGER FOR FIREPLACE HEADER USE 16D'S PER SIMPSON
10/25/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) PORCH TO BEAM CONNECTIONS NOT DONE 2) MISSED ONE PA ON WEST WALL FRONT SHEAR 3) SW4, SW3 SHEAR SHORT NAILED 4) DOUBLE STUDS UNDER GIRDER 5) CHANGE NAIL IN HUS26-TO 16D'S 6) ADD H34 TO FRONT PARAPET ROOF DIAPHRAM PER DETAIL 7) ADD LATERAL BRACES PER TRUSS DRAWINGS
10/21/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) GARAGE ROOF AND CLIP OK