Permit: T02CM01763

Parcel: 126181040

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/17/2002 FRAMING Approved IVRS - Inspection 0000*/ 1) OK TO SHEETROCK
06/27/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) JACUZZI REQUIRES A SEPERATE CIRCUIT, WITH AN ACCESS PANEL FOR MAINTAINING THE MOTOR/PUMP 2) IS TOILET COMPARTMENT WALL TO BE FURRED OUT ? 3) INSTALL DRYER DUCT 4) FIRE BLOCK SOFFIT 5) X BRACE TRUSSES 6) INSTALL KNEE BRACES AT 48" ON CENTER PER PLAN ON WEST GABLE 7) GAS WHATS THE PLAN 8) NEED PLATFORM FOR WATER HEATER 8) BLOCK TRUSSES AT INTERIOR BEARING WALL 9) LEAVE COPY OF TRUSS DRAWINGS ON SITE 1) NEED COLLAR TIES AT NEW OVER FRAMING BAY WINDOW AREA 11) BUILT UP BEAM NOT ON PLAN AT BAY WINDOW 12) USE 10D COMMON NAILS IN HANGER 13) TIE OLD ROOF STRUCTURE INTO NEW AT ROOF LINE