Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/17/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ 1) OK TO SHEETROCK |
| 06/27/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) JACUZZI REQUIRES A SEPERATE CIRCUIT, WITH AN ACCESS PANEL FOR MAINTAINING THE MOTOR/PUMP 2) IS TOILET COMPARTMENT WALL TO BE FURRED OUT ? 3) INSTALL DRYER DUCT 4) FIRE BLOCK SOFFIT 5) X BRACE TRUSSES 6) INSTALL KNEE BRACES AT 48" ON CENTER PER PLAN ON WEST GABLE 7) GAS WHATS THE PLAN 8) NEED PLATFORM FOR WATER HEATER 8) BLOCK TRUSSES AT INTERIOR BEARING WALL 9) LEAVE COPY OF TRUSS DRAWINGS ON SITE 1) NEED COLLAR TIES AT NEW OVER FRAMING BAY WINDOW AREA 11) BUILT UP BEAM NOT ON PLAN AT BAY WINDOW 12) USE 10D COMMON NAILS IN HANGER 13) TIE OLD ROOF STRUCTURE INTO NEW AT ROOF LINE |