Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/06/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/03/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) A REFEE HAS BEEN ASSESED FOR THIS INSPECTION, MULTIPLE INSPECTIONS HAVE BEEN MADE WITH NO PROGRESS ON JOB SITE |
| 05/31/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL PROTECT LAUNDRY VENT 2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT LAUNDRY VENT (ROOFING PAPER) 3) MISSING 2 JOIST'S IN MASTER BEDROOM TO SUPPORT HVAC ON ROOF 4) MISSING BOLTS AT TRIPPLE 2 X 10 BEAM 5) DWV'S FAILED WATER TEST 6) RED HEADS NOT PROPERLY INSTALLED AT MASTER BATH AREA PULLED OUT BY HAND CHECK ALL RED HEADS 7) NOT 3050 GAS PRESSURE TEST NOT ON PERMIT IN IVR |
| 05/28/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PLANS PERMIT ON SITE 2) NEXT FAILURE WILL RESULT IN A RE-FEE 3) PLUMBING NOT READY |