Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/01/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 06/27/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) LOAD ROOF AND ANCHOR 3 POINT TRUSSES AT REAR WALL 2) LOOSE ROOF PANELS MUST BE NAILED 3) DO NOT RECALL THIS INSPECTION UNTIL ALL PREVIOUS INSPECTION ITEMS ARE CORRECTED |
| 06/27/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) ROOF PANELS STILL LOOSE 2) SEE ITEMS 1 AND 4 ABOVE 3) RE-INSPECTION FEE HAS BEEN ADDED |
| 06/26/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) LOOSE ROOF PANELS 2) STRAP NON-CABIN TIED TOP PLATES 3) STRAP END OF BEAM AT ENTRY WEST SIDE 4) SHEARWALL P1 REQUIRES TRANSFER TO TRUSS PER (5A/SD3) |