Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T02CM01700

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/17/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST OK 2.) COPPER OK WATER TEST 3.) WILL INSPECT WATER HEATER ON FINAL 4.) OK TO COVER WALLS.
04/16/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) STILL NO TEST ON DWV PIPING ADDED BY T.I. 2.) A TRAP ARM MAY NOT BE REDUCED A TRAP IS TO BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS ATTACHED. 3.) WATER CLOSET FLUSH HANDLE ON WRONG SIDE 4.) WILL LOOK AT WATER HEATER ON INTERMEDIATE 5.) USE APPROVED STRAPPING ON TRAP ARMS.
04/11/2002 PLUMBING - ROUGH, SOIL Not ready for Inspection PERMANENT LADDER REQUIRED FOR WATER HEATERS 8' AFF. NEED TEST ON DWV