Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/16/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY 3.) OK TO BACKFILL TRENCH. |
| 04/11/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*ROUGH PLBG. INSTALLED NOT TO PLAN. 2.) CAN NOT USE FLAT FACE BUSHINGS IN A HORIZONTAL DRAIN. THIS FITTINGS MAY BE USED IN VERTICAL DRAINAGE ONLY SEE SECTION: 311.5 94 UPC & INTERPETATIONS. 3.) RE TEST SYSTEM 4.) OK TO BACKFILL OTHER TRENCHES NOT PERTAINING TO WHERE BUSHING IS. |