Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/28/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/25/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) REPLACE BOTTOM PLATE UNDER STAIRS WITH TREATED LUMBER 2) COMPLY WITH DETAIL 61 PG AD4 OR PROVIDE REVISION FOR TRUSS CALC'S 3) OK TO INSUALTE EXCEPT BOTTOM OF STAIN LEAVE EXPOSED |
| 06/21/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) PROVIDE ENGINEERING FOR TRUSS CONNECTIONS AT BOTTOM OF STAIRS 2) COMPLY WITH DETAIL 61 PG AD4 AND DETAIL #62 3) PROTECT ALL PLUMBING WITHIN 1/2 FROM EDGE OF STUD CHECK 1ST AND 2ND FLOOR 4) PROVIDE FIRE BLOCKING RIGHT SIDE OF STAIRS 5) CLIP JACK TRUSSES 6) PROTECT ELECTRICAL WITHIN 1 1/4 FROM EDGE OF STUD 7) REPLACE STUD NORTH WALL 8) REPLACE STUD NORTH WALL 8) REDO ELECTRIC AT 2ND FLOOR NORTHWAY 9) MASTER BATH DRAIN HAS NEGATIVE PITCH 10) MISSING TRUSS 2ND FLOOR MEASURES 33" ON CENTER SHOULD BE 24" ON CENTER 11) HOLDOWNS AT LAUNDRY ROOM MISSING BULB 12) NO RISER ON PANEL |
| 06/19/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) GAS PRESSURE TEST AT 6 PSI, 10 PSI MINIMUM REQUIRED 2) PROVIDE WATER TEST FOR ALL DWV'S 3) SECURE GAS LINE AT WATER HEATER AREA 4) HOLDOWN RIGHT SIDE OF STAIRS MISSING BOLT AND FIRE BLOCKING 5) WATER HEATER FLEU REQUIRES 1" CLEARANCE FROM COMBUSTIBLES 6) PROVIDE POSITIVE PITCH FOR CONDENSATE LINES AND SECURE 7) SEAL FLOOR WHERE CONDENSATE LINES PASS THROUGH 8) STOPPED INSPECTION AT 2ND FLOOR LANDING |