Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/29/2004 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FIRE BLOCKS MISSING AT HIGH CEILING AND ENTRY INSULATION TO BE USED 2) HIGH CEILING LIGHTS TO BE WIRED WHEN SCAFFOLD INSTALLED 3) OK TO INSULATE 4) CALL FOR FIRE BLOCK AFTER INSULATION AND BEFORE DRYWALL |
|
| 12/23/2004 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection You must have official original inspection card and proof of all prior inspections Fire blocking missing at great room and entry Fire stop missing at fireplace Combustible material within 2" of fireplace "B" vent Nail protect a/c copper at dark room Ground all metal electric boxes Provide patio door illation instructions Door warped 2" High ceiling lights not wired Repair two leaks at plumbing and floor Provide listing on fire suppression cross connection device No change from 12/20/04 inspection Stopped inspection Too many items |
|
| 12/20/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANGER MISSING IN OFFICE 2) FIRE BLOCKS MISSING GREAT ROOM 3) FIRE STOP MISSING AT FIRPLACE/THROUGHOUT 4) COMBUSTIBLE MATERIAL WITHIN 2" OF FIREPLACE B-VENT 5) NAIL PROTECT A/C COPPER 6) NAIL PROTECT COPPER ? ROD 7) GROUND MEATAL BOXES 8) PATIO DOORS BOWED. PROVIDE MANUFACTURERS INSTALLATION MANUAL 9) HIGH CEILING LIGHTS NOT WIRED 10) LEAK LEFT DUEL BATH (2) 11) PROVIDE LISTING ON CROSS CONNECTION PRETENSION VALVE |
|
| 12/10/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS/PERMIT 2) NO ACCESS 3) HOUSE LOCKED 4) DUE TO WORK LOAD CANNOT MAKE P.M. INSPECTION |
|
| 11/22/2004 | FRAMING | Denied | IVRS - Inspection : There is no access to the site.| 920*/ 1) DANGEROUS ROAD-NO ACCESS TO SITE |
|
| 11/15/2004 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925*/ 1) NO PLANS PERMIT OR PRIOR INSPECTION REPORTS ON SITE 2) NO VEHICLE ACCESS TO SITE. TRUCK BLOCKING ROAD. YOU MUST PROVIDE ACCESS TO SITE 3) NEXT FAILURE WILL BE CHARGED REINSPECTION FEE |
|
| 11/12/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY PER ANDY | |
| 11/08/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY PER OWNER | |
| 10/15/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) LAUNDRY MISSING HD BOLT, FB AND RED HEADS 2) SUPPORT 1/2" GAS LINE AT 6" ON CENTER 3) DRAIN LEAKS 4) TOILET VENT MUST ATTACH ABOVE CENTER LINE OF DRAIN CHECK ALL 5) FIRE BLOCKS MISSING THRU-OUT 6) BLOCK MECH BOOTS 7) F/P "B" 2" CLEARANCE AND FIRESTOP 8) MAKE UP ALL GROUNDS 9) GROUND ALL METAL ELECTRIC BOXES 10) STAIR RISE EXCEEDS 7 8/4" 11) PROVIDE MAX 30 PSI GAS GAUGE 12) WIRING NOT COMPLETE 13) LAV DIRTY ARM MORE THAN 42" AND 1 1/2" 14) CLIP TRUSSES AT BEARING PT 15) FHA STRAP PLATE CUTS 16) 36" GUARD RAILS REQUIRED 17) INSULATE DUCT "Y'S" |
|
| 10/14/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 09/10/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES 2) MAKE UP ALL GROUNDS AND CONNECT WITH A MECHANICAL FASTENERS 3) PROVIDE GROUND PIG TAILS FOR ALL SWITCHES AND OUTLETS 4) NO CITY OF TUCSON APPROVED PLANS ON SITE, ALSO INSPECTION CARD |
|
| 07/23/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |