Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/18/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/13/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) 2 X 8 RAFTERS EXCESSIVELY NOTCHED 2) PROVIDE POSITIVE CONNECTION INTERIOR BEARING FROM MASONRY TO RAFTERS 3) INSTALL BLOCKING BETWEEN STUDS AT JOINTS ( EXTERIOR SHEATHING) 4) X CROSS BRACE 1ST AND 3RD TRUSS EACH END 5) INSTALL ANCHOR BOLTS WITHIN 12" EACH END BOTTOM PLATES 6) PLAN CALLS FOR 2 X 8 RAFTERS TO BE AT 16" SPACING 7) INSTALL ROOF JACK AT PLUMBING PENETRATIONS (ROOF) |