Permit: T02CM01639

Parcel: 10703138A

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
07/03/2002 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000*SHT. MTL. SUPPLY CEILING CANS, EXTENDING UP INTO ATTIC. NEED TO BE INSULATED. 2.) SHORTEN LENGTH OF FLEX DUCT TO LONG CAUSE DUCT TO LOSE ITS SHAPE. PROPER LENGTH ALLOWS DUCT TO RETAIN ITS FULL DIAMETER.
06/03/2002 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) AC UNITS OVER 5 TON NEED DUCT SMOKE DETECTORS IN THE RETURN 2.) AFTER RELOCATING THE UNIT HEATER, BE SURE TO MAINTAIN 10' CLEARANCE FROM EVAP. COOLERS ON VENT PIPING. 3.) BATHROOM MISSING EXHAUST FAN & DUCT. OK TO PROCEED W/SHEET ROCK & CEILING GRID.