Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :*CORRECTIONS HAVE BEEN MADE. AS PER LAST REQUEST/ LAST INSP ON JOB PLEASE PROVIDE GAS CARD. | |
| 11/09/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT @ WATER HTR FLU VENT AND @ APPLIANCE COLLAR 2)KITCHEN SINK NOT INSTALLED |
|
| 05/24/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) ONLY ONE SLIP NUT ALLOWED ON THE OUTLET SIDE OF THE TRAP 1003.2 94 UPC. THIS BLDG HAS NON METALLIC INTERIOR WATER PIPING 3) SEE 608.5 T & P RELIEF DRAIN-FULL SIZE, APPROVED MATERIAL |