Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
10/08/2003 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
10/01/2003 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) APPROVED CONNECTOR NEEDED FOR TOP OF SUB-PANEL BUSHINGS NOT ALLOWED 2) DO NOT BUNDLE CABLE TO SUB-PANEL 3) INSTALL GROUNDING CONDUCTORS AS PER MANUFACTURERS INSTRUCTIONS 4) PROTECT CABLES FROM SHARP METAL EDGES 5) CONNECTOR NEEDED FOR BOXES NOT BUSHINGS AND EXHAUST FANS 6) GFCI TO BE AT FRONT OF UNIT #2
08/29/2003 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/1) EXTERIOR AND INTERIOR BOXES TO BE MADE UP - GROUND METAL BOXES. 2) A LICENSED ELECTRICAL CONTRACTOR IS TO PERFORM WORK. THIS IS A DUPLEX.