Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/15/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/11/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*DOOR LOCKED NO ACCESS. |
| 07/09/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 WITHOUT THE USE OF AN ADDITIONAL CLEAN OUT. 2.) WATER CLOSET INCOMPLETE. 3.) ALL FIXTURES TO BE SECURED AND CAULKED. 4.) WHERE IS YOUR REDUCED PRESSURE BACKFLOW PREVENTER? AND CERTIFICATION. 5.) WHERE CLEAN OUT COVERS ARE REQUIRED USE APPROVED COUNTER SUNK TAPPED, CLEAN OUT PLUGS WITH APPROVED SCREWS. |