Permit: T02CM01629

Parcel: 13706018C


Addresses:

5323 S 12TH AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T02CM01629

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/24/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000* 1.) ABS UNDERGROUND OK 2.) COPPER OK 3.) OK TO COVER FLOOR AND WALLS. 4.) GAS RE-ROUTED AND RETESTED OK 5.) REVIEW NOTES FROM HEALTH DEPT AND COMPLY, REVISE PLAN IF NECESSARY AND CALL IN INSPECTION FOR ALL RESULTING WORK.
06/20/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) CAP OFF ABANDONED PIPING WITH APPROVED CAPS 2.) COPPER AND GALVANIZED MAY NOT BE DIRECTLY CONNECTED 3.) A FURNCO (UNSHIELDED) MAY NOT BE USED INSIDE OR UNDER BLDG. 4.) PROTECT COPPER WHERE PASSING THROUGH MASONRY 5.) WATER TEST FOR 3 COMP SINK, AND MOP SINK OK 6.) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE THROUGH WYE BRANCH OR EQUILDENT. 7.) GAS SHALL BE A MINIMUM OF 12" BELOW GRADE.