Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* 1.) ABS UNDERGROUND OK 2.) COPPER OK 3.) OK TO COVER FLOOR AND WALLS. 4.) GAS RE-ROUTED AND RETESTED OK 5.) REVIEW NOTES FROM HEALTH DEPT AND COMPLY, REVISE PLAN IF NECESSARY AND CALL IN INSPECTION FOR ALL RESULTING WORK. |
| 06/20/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.) CAP OFF ABANDONED PIPING WITH APPROVED CAPS 2.) COPPER AND GALVANIZED MAY NOT BE DIRECTLY CONNECTED 3.) A FURNCO (UNSHIELDED) MAY NOT BE USED INSIDE OR UNDER BLDG. 4.) PROTECT COPPER WHERE PASSING THROUGH MASONRY 5.) WATER TEST FOR 3 COMP SINK, AND MOP SINK OK 6.) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE THROUGH WYE BRANCH OR EQUILDENT. 7.) GAS SHALL BE A MINIMUM OF 12" BELOW GRADE. |