Permit: T02CM01621

Parcel: 137055220


Addresses:

1217 W IRVINGTON RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02CM01621

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/12/2002 PLUMBING - FINAL Approved
07/09/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SHAMPOO BOWLS NOT SECURED 2.) PROVIDE LISTING FOR CORRUQATED FLEXIBLE TAILPIECE 3.) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 WITHOUT THE USE OF AN ADDITIONAL CLEAN OUT 4.) DISHWASHER DRAIN HOSE MUST BE SECURED AT DRAIN BOARD HEIGHT. 5.) SPINK HOSE CLAMP ON T & P DRAIN SO AS TO NOT BE A HAZARD TO KNEES OR SHING