Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
Permit Number - T02CM01620
Inspection Description - PLUMBING - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2002 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection 0000* | |
04/18/2002 | PLUMBING - ABOVE CEILING | Denied | 1.) WASTE & VENT SYSTEM. 2.) OVERHEAD WATER DISTRIBUTION. IS OK 3.) OK TO DRYWALL UPON BLDG. INSPECTORS APPROVAL. 4.) HORIZONTAL VENTS REQUIRE A HANGER OR STRAP EVERY 4'-0" ON 1 1/2 & 3" VENTS. 5.) NOTE CLOSET RING HAS NOT BEEN INSTALLED @ THIS TIME. 6. 1/2" COPPER @ SOUTH WALL DROP REQUIRE A ISOLATOR EVEN IF HOLE HAS BEEN CUT TO BIG. |