Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/30/2002 FRAMING Approved IVRS - Inspection 0000*
05/29/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) MISSING HT22'S HD'S AT SHEARWALL 2) CHECK BEARING AT INTERIOR (BOTH SIDES) 3) PEX TO CLOSE TO LIGHT CAN HALL WAY 4) BANG PLATE AT VENT MIDDLE BEDROOM TOP PLATE 5) MISSING FURNACE FLUE WEST FURNACE 4 STUD SHOES 6) LABEL CONDENSATE PRIMARY SECONDARY LINES 7) CONNECT FREON LINES 8) GAS LINE HOLDING PRESSURE 9) LOOSE BOTTOM PLATE FRONT BEDROOM 10) INSULATE FIREPLACE 11) CHECK ZIP TIE, WEST FURNACE RETURN DUCT LOOSE INSULATION 12) REAR PORCH WINDOW SAFETY GLASS, NEXT TO DOOR 13) ALL REAR AND FRONT TRUSS ARE 4 PT BEARING ADJUST VERTICAL SUPPORT TO HIT ON BEARING WALL