Permit: T02CM01599

Parcel: 110064960


Addresses:

2972 N CARDELL CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/16/2002 FRAMING Approved IVRS - Inspection 0000*
07/11/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEM 11 FROM 7/5/02 NOT COMPLIED WITH ALL ELSE-OK
07/05/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PLUMBING OUTSIDE OF WALL CAVITY 2) FIREBLOCK CHASE IN GARAGE 3) SUPPORT 1/2" GAS LINE AT 6" ON CENTER 4) WIRES OUT OF ELECTRIC BOX (BATH) (2 EACH) 5) BLOCK MECHANICAL 3 SIDES 6) W/C REQUIRES 15" CLEARANCE 7) FIRE BLOCK WINDOW POP OUTS 8) BEARING WALL STUD MISSING 9) BEARING WALL OVER BORED 3 STUDS 10) CUT ENTRY HEADER STRAPS 11) NOTE: 13 PAGE S3 REQUIRES 3 X 6 LEDGERS AND 2 X 4 USED