Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 08/15/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 07/26/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) INTERIOR PLUMBING DONE WITHOUT INSPECTION, APPEARS TO BE SUBSTANDARD-EXISTING PLUMBING TO NEW ADDITION NEED LONG SWEEP 90 DEGREE WITH 1/4" PER FOOT MINIMUM SLOPE AND WRAPPED WITH 1/4" FOAM TO PROTECT WHERE ENCASED IN CONCRETE-VERIFY PROPER VENT AND FOOTING AT PLUMBING DONE WITHOUT INSPECTIONS |
| 07/25/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PLANS ON SITE |