Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM01511
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/17/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
05/16/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE TOP PLATE BLOCKING FOR GARAGE SOUTH SHEAR WALL #1 2) SHOWER NOT VENTED (SEE PLAN) 3) BEDROOM 2 SHEAR WALL 2 MISSING SHEAR BLOCKS 4) LAUNDRY DRYER WIRE TRAPPED-DAMAGED 5) SILL PLATE NORTH OF ENTRY MISSING ANCHOR BOLTS 6) FIRE BLOCK MISSING SOUTH OF PATIO DOOR AND MASTER BEDROOM 7) FIREPLACE OFFSET ELBOW NOT FULLY STRAPPED 8) STUD MISSING OVER SPAN AT HALL CLOSET 9) SUPPORT WIRES AT 4' ON CENTER AND AT SERVICE |