Permit: T02CM01509

Parcel: 128010330


Addresses:

6211 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T02CM01509

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/20/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) OK TO BACKFILL TRENCH.
05/16/2002 PLUMBING - ROUGH, SOIL Denied 1.) MUST USE L SWEEPS ON FLAT VENT SYSTEM 2.) MUST USE BELL REDUCES ON ALL HORIZONTAL WASTE LINES. 3.) MUST USE DOUBLE FIXTURE FITTINGS FOR LAVATORYS. 4.) MIN TRAP ARM SIZE IS TWO TIMES THE PIPE DIAMETER FO DRAIN LINES USED FOR MOP SINK 5.) RE TEST SYSTEMS.