Permit: T02CM01508

Parcel: 12809006B


Addresses:

5441 E 22ND ST #115


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T02CM01508

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/11/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) WASTE & VENT SYSTEM IS OK 3.) OVERHEAD WATER DISTRIBUTION IS OK 4.) OK FOR DRYWALL.
04/10/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) WASTE & VENT SYSTEM REQUIRES WATER TEST ALL THE WAY TO ROOF. 2.) VENT SYSTEM IS OVERLOADED ON FIXTURE UNITS. APPROVED PLAN CALLS FOR 3" VTR. 3.) CLOSET RINGS NOT INSTALLED.