Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/26/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*APPROVED BOTH 1 & 2. |
| 06/25/2002 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL EAST SIDE UNIT OK TO COVER RECALL FOR WEST SIDE ITEMS 2-3.. #4 WATER BOND & GAS BONDS TIED IN OK APPROVED. 2.) SECURE BRANCH CIRCUITS ON WEST WALL WHERE THEY. EXIT TO SERVICE. 3.) HALL WALL MOUNT BOX GOING INTO BATH ROOM SEAL 1/2 HOLE FACING STUD NO COMBUSTIBLES TO BE EXPOSED TO INSIDE OR BOX THEY ARE TO BE FULLY ENCLOSED. |