Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/31/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST ON RISER TO 10' OK 2.) GREASE INTERCEPTOR OK 3.) SEWER 4" ABS FROM INTERCEPTOR, PICKING UP 4" BLDG. DRAIN AND TIE-IN TO EXISTING OK 4.) 1 1/2" SCH 40 PVC YARDWATER OK 5.) OK TO COVER ALL AREAS. |