Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/25/2002 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST ONE TEN FOOT RISER OK 2.) OK TO BACKFILL * NOTE: PLUMBER IS TO TAKE CARE BACKFILLING AND INSURE THAT PROPER SLOPE IS MAINTAINED ON ALL CLOSET BENDS, AND TRAP ARMS. |
|
| 11/21/2002 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*1.) PLUMBER CUT OUT APPROVED DOUBLE FIXTURE FITTING, AND INSTALLED DOUBLE SANTEE. DOUBLE SANITARY TEES MAY BE USED WHEN THE BARREL OF THE FITTING IS AT LEAST TWO PIPE SIZES LARGER THAN THE LARGEST INLET. 706.2 94 UPC. | |
| 11/19/2002 | PLUMBING - ROUGH, SOIL | Denied | A TRAP ARM REQUIRES A MINIMUM OF TWO PIPE DIAMETERS BETWEEN THE WEIR OF THE TRAP AND THE POINT OF VENT. |