Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM01445

Parcel: 141170130


Addresses:

10371 E DANWOOD WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/10/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
05/28/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ADDITIONAL NAILING REQUIRED AT GARAGE FRONT SHEAR (MAXIMUM STUD SPACING 16" ON CENTER) 2) ADD CLIPS TO FRONT GABLE TRUSS WHERE OSB IS CUT 3) ADD CLIPS AT REAR GABEL WHERE OSB JOINT IS AT JOINT OF TOP PLATE DOUBLER 4) ROOF SHEATHING NAILING OK