Permit: T02CM01410

Parcel: 125171670

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
04/26/2002 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
04/18/2002 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*/ 1) BOND BEAM TOO SHALLOW. BOND BEAM BLOCK INSTALLED UP SIDE DOWN. YOU MAY EXTEND BOLTS AND INSTALL ONE MORE COURSE OF BLOCK ABOVE IF HEIGHT PERMITS. REBAR MUST BE AT LEAST 1 1/2" BELOW TOP SURFACE OF BLOCK
04/17/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) BOND BEAM STEEL NOT IN
04/12/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) 4FT LIFT OK 2) CALL FOR INSPECTION OF BOND BEAM