Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/26/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 06/25/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) CLIP GABLE END TRUSSES TO END WALLS AT 31" ON CENTER 2) GABLE END TRUSSES HAVE BEEN NOTCHED FOR LOOK OUTS-PROVIDE TRUSS MANUFACURE AND CITY OF TUCSON APPROVED REPAIR 3) "X" BRACE REQUIRED ON 3 END TRUSSES 4) ROOF PANELS ON SOUTHWEST, NORTHWEST AND NORTHEAST CORNERS OF BUILDING DON NOT HAVE ENDS/EDGES NAILED 5) PROVIDE CITY OF TUCSON APPROVED TRUSS DRAWINGS |