Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM01395

Parcel: 136011690


Addresses:

8265 E SUNDEW DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM01395

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/02/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/18/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) MISSING PAHDS
04/15/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PAHDS MISSING 2) A35'S INCORRECTLY NAILED (BLOCKING TRUSSES AT BEARING) 3) GARAGE HEADER BEARING NOT STRAPPED PER DETAILS 4) STOPPED INSPECTION