Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/08/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/07/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK COMBUSTION/RELIEF STUD BAY 2) ADD MIDSPAN CROSS BRACING 3) REPAIR INTERIOR KITCHEN WALL 4) CORRECT TC NAILING WHERE NEEDED 5) SHIM PLATES OVER KITCHEN WINDOW AND DINING WINDOW AND WHERE NEEDED 6) CHECK MASTER BATH SHEARWALL CONNECTION |