Permit: T02CM01358

Parcel: 137052950


Addresses:

5167 S 13TH AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/05/2003 FRAMING Approved IVRS - Inspection 0000*
01/03/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE NAIL PROTECTION FOR ALL WIRES WITHIN 1 1/4" OF STUD SURFACE LAUNDRY 2) BATHROOM EXHAUST FAN MUST EXHAUST OUTSIDE 3) NAIL PROTECT BATHROOM W/C VENT 4) PROVIDE FURNACE HIGH/LOW COMBUSTION AIR 5) ALL WIRES MUST TERMINATE IN APPROVED BOXES 6) WIRES OUTSIDE OF WALL CAVITY AT SERVICE 7) BEDROOM WINDOW SILLS MORE THAN 44" ABOVE FLOOR 8) BEDROOM WINDOWS NOT PER PLAN, BUILD TO PLAN OR REVISE PLAN AND HAVE APPROVED 9) MECHANICAL NOT PER PLAN REVISE PLAN TO AS BUILT 10) DUCT " Y'S" NOT INSUALTED 11) GAS LINE NOT BONDED 12) PEX OUTSIDE OF WALL AT BATH 13) STOPPED INSPECTION TO MANY ITEMS
11/13/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ALL INTERMEDIATES MUST BE COMPLETED BEFORE FRAMING INSPECTION CAN BE PASSED, ELECTRICAL, PLUMBING, GAS PRESSURE AND MECHANICAL, ETC...