Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/05/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/03/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE NAIL PROTECTION FOR ALL WIRES WITHIN 1 1/4" OF STUD SURFACE LAUNDRY 2) BATHROOM EXHAUST FAN MUST EXHAUST OUTSIDE 3) NAIL PROTECT BATHROOM W/C VENT 4) PROVIDE FURNACE HIGH/LOW COMBUSTION AIR 5) ALL WIRES MUST TERMINATE IN APPROVED BOXES 6) WIRES OUTSIDE OF WALL CAVITY AT SERVICE 7) BEDROOM WINDOW SILLS MORE THAN 44" ABOVE FLOOR 8) BEDROOM WINDOWS NOT PER PLAN, BUILD TO PLAN OR REVISE PLAN AND HAVE APPROVED 9) MECHANICAL NOT PER PLAN REVISE PLAN TO AS BUILT 10) DUCT " Y'S" NOT INSUALTED 11) GAS LINE NOT BONDED 12) PEX OUTSIDE OF WALL AT BATH 13) STOPPED INSPECTION TO MANY ITEMS |
| 11/13/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL INTERMEDIATES MUST BE COMPLETED BEFORE FRAMING INSPECTION CAN BE PASSED, ELECTRICAL, PLUMBING, GAS PRESSURE AND MECHANICAL, ETC... |