Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T02CM01356
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2003 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 05/19/2003 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*NEED EXTRA RECEPTACLE BEHIND KIT SINK. LABEL SERVICE THAT NON METALIC PLUMBING BEING USED. A MAINTANCE RECEPT REQUIRED FOR ALL A/C COMPRESSOR AREAS. AIR HANDLERS NOT READY, LABEL ALL PERMANET DATA. BOX REQUIRE FOR BATHROOM FIXTURES. INSTRUCTION FOR TEMP POWER LEFT AT SITE. NEED LOCK OUT DEVICE FOR WATER HEATER. |