Inspection Status: Approved
Inspection History: STUCCO MESH
| Date |
Description |
Inspector |
Results |
Comments |
| 08/05/2002 |
STUCCO MESH |
|
Approved |
IVRS - Inspection 0000* |
| 07/25/2002 |
STUCCO MESH |
|
Denied |
IVRS - Inspection 0999*/ 1) CONNECTIONAL FRAME OVER LAUNDRY ROOM DOES NOT HAVE A POSITIVE CONNECTION TO BEARING STRUCTURE 2) DOUBLE 2 X 8 RIDGE BEAM MUST BEAR ON STRUCTURAL MEMEBERS. PROVIDE A CITY APPROVED DETAIL OF BEARING 3) POP OUT DOUBLE TOP PLATE NOT PER 7/4 4) GLU LAM BEAM TO POSTS NOT PER 7/4 OR 1/3 5) CANNOT APPROVE STUCCO UNTIL EXTERIOR CLIP IS APPROVED 6) PROVIDE PROOF THAT RAFTERS ARE CLIPPED TO STRUCTURE 7) CLIPPED TRUSSES MUST BE BLOCKED TOP AND BOTTOM |