Permit: T02CM01313

Parcel: 141305240

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM01313

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/29/2002 FRAMING Approved IVRS - Inspection 0000*
05/16/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) MECHANICAL INTERMEDIATE: NEED VARIANCE FROM D. MANN (791-550) RE: LENGTH OF DRYER VENT 2) FRAMING WILL BE APPROVED UPON APPROVAL OF DRYER VENT
05/15/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) H2.5'S ON LEDGER NOT INSTALLED CORRECTLY-(SEE DRAWING ON EDGE OF 3RD STUD) 2) STRAPS AT ELECTRIC HOME RUNS MUST BE STRUCTURAL FHA STRAPS AND MUST BE NAILED PER SIMPSON SPECC. (3 NAILS EACH END)
05/14/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) REPLACE BANG PLATES WITH FULL LENGTH FHA STRAPS AT ELECTRIC HOME RUNS (NOTE: IF YOU DRILL THE HOLE AT ELAST 2 X DIAMETER APPART, THEN NO STRAP IS REQUIRED) 2) DRYER VENT EXCEEDS LENGTH ALOOWED BY CODE 3) CLIP STAIRWAY LANDING LEDGER TO STUDS 4) RESTORE FRAMING AND ELECTRIC AT RELOCATED WINDOW