Permit: T02CM01312

Parcel: 141305940


Addresses:

10647 E OAKBROOK ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM01312

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/30/2002 FRAMING Approved IVRS - Inspection 0000*
05/28/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) WEST SIDE OF SINGLE CAR HEADER NEEDS ANOTHER TRIMMER 2) CORRECT OVER NOTCHED BEARING AND SHEARWALL STUDS-MANY 3) SUPPORT PLUMBING VENT 90 DEGREE IN LAUNDRY CEILING AND AT WEST 1ST FLOOR TUB 4) RE-INSTALL LAUNDRY CEILING LIGHT AND AT BEDROOM #4 CEILING 5) GROUNT TUB 6) TIGHTEN HOLDOWNS 7) NEED STAIR HEADER/BEARING CORRECTIONS 8) BLOCK MECHANICAL BOOT IN PANTRY 9) SHIM HEADERS WHERE NEEDED 10) BLOCK BOTTOM CHORD OF TRUSSES OVER FRONT DOOR 11) FHA STRAP PLATES AT PLUMBING VENT IN #4 BED EXTERIOR WALL 13) ADD OUTLET IN #4 BED