Permit: T02CM01309

Parcel: 141305230

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM01309

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2002 FRAMING Approved IVRS - Inspection 0000*
06/18/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) 2ND FLOOR HALL BATH WATER CLOSET NOT PER CODE (MUST RISE VERTICALLY TO AT LEAST 6" ABOVE FLOOD RIM OF TOILET 2) SHIM HEADERS IN BEARING WALLS AS NEEDED FOR BEARING 3) CONDENSATE DRAIN AT NORTH FAU PRIMARY AND SECONDARY INTER CONNECTED 4) FHA STRAP VENT PENETRATION AT HALL BATH 2ND FLOOR 5) PEX WATER LINES MUST BE MINIMUM 12" FROM CAN LIGHTS