Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM01309
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
06/18/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) 2ND FLOOR HALL BATH WATER CLOSET NOT PER CODE (MUST RISE VERTICALLY TO AT LEAST 6" ABOVE FLOOD RIM OF TOILET 2) SHIM HEADERS IN BEARING WALLS AS NEEDED FOR BEARING 3) CONDENSATE DRAIN AT NORTH FAU PRIMARY AND SECONDARY INTER CONNECTED 4) FHA STRAP VENT PENETRATION AT HALL BATH 2ND FLOOR 5) PEX WATER LINES MUST BE MINIMUM 12" FROM CAN LIGHTS |