Permit: T02CM01282

Parcel: 132191160

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T02CM01282

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) WASTE AND VENT SYSTEM WATER TEST OK 4) OK FOR DRYWALL
05/30/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1) MUST TEST GAS SYSTEM IN ITS ENTIRETY 2) MUST LOCATE HANGERS FOR OVERHEAD WATER DISTRIBUTION EVERY 6' -0'' 3) WASTE & VENT SYSTEM IS OL WATER TEST OK 4) MUST INSTALL ROOF SACKS FOR ALL ROOF PENETRATIONS. 5) NO CLOSET RINGS.
05/28/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION
05/23/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*
05/23/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY ON WASTE AND VENTS NO TEST HANGERS MISSING. PLEASE NOT HANGERS REQUIRED 4' FOR ABS 2) PROVIDE MID STORY ANCHORS ON ALL ABS AND COPPER WATER PIPING 3) PLEASE SEE SPECS FOR INSULATION ON WATER LINES 4) CODE VIOLATION ON ANSOL VALVE HAVE PLUMBER ON JOB AT TIME OF NEXT INSPECTION