Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/08/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/02/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) MARKED BEARING LOCATION ON TRUSSES MUST BEAR ON WALL. PROVIDE ENGINEER APPROVED REPAIR FOR TRUSSES WHOSE BEARING POINT MISSED WALL. 2) UNABLE TO COMPLETE THIS INSPECTION WITHOUT TRUSS CALCS. ROOF SHEATHING NAILING OK 3) ADDITIONAL NAILING REQUIRED AT GARAGE FRONT SHEAR 4) AT CORNERS WHERE TOP PLATES DO NOT LAP, THEY MUST BE STRAPPED |