Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM01261

Parcel: 141304510

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM01261

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/02/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) MARKED BEARING LOCATION ON TRUSSES MUST BEAR ON WALL. PROVIDE ENGINEER APPROVED REPAIR FOR TRUSSES WHOSE BEARING POINT MISSED WALL. 2) UNABLE TO COMPLETE THIS INSPECTION WITHOUT TRUSS CALCS. ROOF SHEATHING NAILING OK 3) ADDITIONAL NAILING REQUIRED AT GARAGE FRONT SHEAR 4) AT CORNERS WHERE TOP PLATES DO NOT LAP, THEY MUST BE STRAPPED