Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T02CM01215
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/11/2002 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection 0000* | |
05/31/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*/ 1) ABS PIPING AT KITCHEN SINK VENT PIPING, CANNOT HAVE 90 DEGREE TURNS BELOW THE FLOOD RIM OF THE SINK. 45 DEGREE FITTING OK 2) COPPER SUPPLY LINES CANNOT HAVE JOINTS BURIED UNDER THE SLAB 3) OK TO GROUT 1ST LIFT. CALL FOR INSPECTION FOR NEXT LIFT, BOND BEAM ETC... |