Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/24/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/21/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) ADD 2 X 4 BLOCKS AT CMU TO ROOF FOR SHEET ROCK NAILING 2) YOU HAVE AROUND 10 OUTLETS ON A ISLAND CIRCUIT AND CAN'T FIND POWER SOURCE FOR NEW ADDITION 3) ENDS, BEARING RAFTERS ARE NOT TIED DOWN TO A SECURED PLATE OR MEMBER |
| 05/20/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PLAN CALLS FOR 3 1/2 X 12 GLU LAM BEAM FOR RIDGE 2 2 X 10'S USED 2) BEAM REQUIRES PAT 18 EACH SIDE EACH END NOT INSTALLED |