Permit: T02CM01214

Parcel: 133121670


Addresses:

7800 E CLARENCE PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/24/2002 FRAMING Approved IVRS - Inspection 0000*
05/21/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) ADD 2 X 4 BLOCKS AT CMU TO ROOF FOR SHEET ROCK NAILING 2) YOU HAVE AROUND 10 OUTLETS ON A ISLAND CIRCUIT AND CAN'T FIND POWER SOURCE FOR NEW ADDITION 3) ENDS, BEARING RAFTERS ARE NOT TIED DOWN TO A SECURED PLATE OR MEMBER
05/20/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PLAN CALLS FOR 3 1/2 X 12 GLU LAM BEAM FOR RIDGE 2 2 X 10'S USED 2) BEAM REQUIRES PAT 18 EACH SIDE EACH END NOT INSTALLED