Inspection History: FRAMING

Date Description Inspector Results Comments
05/07/2002 FRAMING Approved IVRS - Inspection 0000*
05/03/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) REVISE PLAN FOR ADDED PLUMBING AND PROVIDE APPROVED TEST 2) GAS SHUT OFF VALVE CANNOT BE ENCLOSED IN WALL 3) ONE BEARING STUD NOTCHED GREATER THAN 25 PERCENT 4) FIRE BLOCK MISSING BY STORAGE 5) WOOD STRUCTURAL MEMBERS NOT ALLOWED WITHIN 2" OF MASONRY FIRE PLACE 6) SUPPORT PEX AT 4' ON CENTER 7) MECHANICAL NOT INSTALLED 8) GROUND ALL METAL ELECTRIC BOXES 9) OUTSIDE GFCI NOT IN