Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/03/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/10/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ITEM 4 FROM 4/9/02 NOT COMPLIED WITH WILL CHECK AT INTERMEDIATE 2) ROOF NOT NAILED TO TJI 30" FROM WEST WALL |
| 04/09/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) EXTERIOR SHEATHIN NOT NAILED TO STUDS ON NORTH AND WEST WALLS SEVERAL PLACES 2) ANCHOR BOLTS MISSING SEVERAL PLACES. REQUIRED WITHIN 12" OF PLATE ENDS AND SPLICES 3) ROOF NOT NAILED SEVERAL PLACES 4) PROVIDE CITY OF TUCSON APPROVED DESIGN OF DOUBLE 2 X HEADER SPANNING 12 PLUS FEET BEARING TJI ROOF JOIST-PRESENTLY NOT PER PLAN |