Permit: T02CM01158

Parcel: 133477090

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/08/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/02/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) NEED POSITIVE CONNECTION TOP PLATE INTO EXISTING AND NEW STUDS ABUTTING EXISTING 2) APPEARS HEADER OVER NEW SLIDER IS SAGGING EVEN THOUGH TECHNICALLY NON BEARING, IT APPEARS BUILT UP HEADER TO SMALL FOR SPAN