Permit: T02CM01094

Parcel: 133443220

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/19/2002 FRAMING Approved IVRS - Inspection 0000*
04/18/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ALL ITEMS NOT COMPLETED
04/17/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) FRONT BEDROOM WINDOW MISSING 2-2 X 6 HEADER OR EQUVALENT 2) HEADER OVER REAR 8' WINDOW REQUIRES 3 1/2" X 5 1/2" TIMBER STRAND 3) INSTALL DTC EXTERIOR NON TRUSS TO TOP PLATES 4) BEDROOM CLOSET NON-BEARING HEADER INSTALL HANGER OR STUD UNDERNEATH 5) SHEAR LADDER-BLOCKING NOT ISNTALLED PER DETAIL 6) INSTALL ATTIC ACCESS AND WALKWAY TO FURNACE