Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/25/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/22/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) DRAINAGE/VENT TEST NOT READY-EMPTY 2) HOLDOWN AT MASTER PATIO DOOR MOVED 1" NORTH WHEN KITCHEN ? 3) SEAL MESH PROTRUSION AT GAS MAIN AND ELECTRIC UNDER MAIN PANEL |
| 03/20/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ADD RED HEAD EAST SIDE OF GARAGE AND HOLD DOWN AT REAR GARAGE 2) SHIM TRIMMERS, HEADERS AND CRIPPLES WHERE NEEDED 3) ADD REDHEAD AT REAR RIGHT BEDROOM EAST WALL 4) CLIP ALL LEDGERS THAT ARE NOT CLIPPED 5) (PAGE 4) HEADER ABOVE ARCH, BETWEEN KITCHEN AND FRONT ENTRY, NEEDS 4 X 4 POSTS (B.U.) 6) STRAP ALL NON-CABIN TIED, INTERSECTING TOP PLATES 7) ATTACH 3RD FIREPLACE FLUE STRAP 8) TIGHTEN HOLDOWN AT MASTER PATIO DOOR 9) TIGHTEN HOLDOWNS IN LIVING ROOM 10) GAS TEST NOT READY 11) DRAINAGE TEST NOT READY 12) WATER SUPPLY OK-3/20 |