Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM01059

Parcel: 136032230

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/29/2002 FRAMING Approved IVRS - Inspection 0000*
04/28/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NEED WATER TEST ON SEWER
04/25/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) NO WATER TEST ON DWV'S OR WATER LINES 2) COMPLY WITH DETAIL 10 DT-1 AT GARAGE 3) COMPLY WITH DETAIL 5 DT-1 4) LOOSE ANCHOR BOLTS THROUGHOUT 5) SUPPORT 4 GANG BOX 6) SECURE WATER LINE AT HALL BATH 7) GROUND ELECTRICAL BOXES